SU-8 microstructure for quasi-three-dimensional cell-based biosensing
dc.contributor.author | Wang, Lina | |
dc.contributor.author | Wu, Ze-Zhi | |
dc.contributor.author | Xub, Bingqian | |
dc.contributor.author | Zhaoc, Yiping | |
dc.contributor.author | Kisaalita, William S. | |
dc.date.accessioned | 2025-04-16T14:38:14Z | |
dc.date.available | 2025-04-16T14:38:14Z | |
dc.date.issued | 2009 | |
dc.description.abstract | A quasi-three-dimensional (quasi-3-D) cell-based biosensor platform microfabricated from SU-8 has been developed and characterized. In this work, SH-SY5Y human neuroblastoma cells were integrated with SU-8 microfabricated microwells with diameters of 100μm. SH-SY5Y cells were differentiated with 1mM dibutyryl cAMP and 2.5μM 5-bromodeoxyuridine. Voltage-gated calcium channel (VGCC) function of SH-SY5Y cells cultured within the microwells (quasi-3-D) versus those cultured on the SU-8 planar substrates (2-D) was evaluated by confocal microscopy with a calcium fluorescent indicator, Calcium Green-1. In response to 50mM high K+ depolarization, cells in microwells were less responsive in terms of increase in intracellular Ca2+ in comparison to cells on 2-D substrates. This study shows that VGCC function of cells within SU-8 microwells was indeed different from that of cells on planar SU-8 surfaces, suggesting that SU-8 microstructure did affect SH-SY5Y cell differentiation with respect to VGCC function and that high-aspect-ratio microstructures are not merely “folded” 2-D structures. Furthermore, these results are consistent with previous 2-D/3-D comparative studies carried out in polymer scaffolds and support the hypothesis that cell calcium dynamics on 2-D substrates may be exaggerated. Overall, this work is supportive of SU-8 micropattern as a viable platform for engineering a quasi-3-D cell culture system for cell-based biosensing against drugs for VGCCs. | |
dc.identifier.citation | Wang, L., Wu, Z. Z., Xu, B., Zhao, Y., & Kisaalita, W. S. (2009). SU-8 microstructure for quasi-three-dimensional cell-based biosensing. Sensors and Actuators B: Chemical, 140(2), 349-355. | |
dc.identifier.uri | https://www.sciencedirect.com/science/article/pii/S0925400509004043 | |
dc.identifier.uri | https://nru.uncst.go.ug/handle/123456789/10831 | |
dc.language.iso | en | |
dc.publisher | Sensors and Actuators B: Chemical | |
dc.title | SU-8 microstructure for quasi-three-dimensional cell-based biosensing | |
dc.type | Article |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- SU-8 microstructure for quasi-three-dimensional cell-based biosensing.pdf
- Size:
- 1.01 MB
- Format:
- Adobe Portable Document Format
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- license.txt
- Size:
- 1.71 KB
- Format:
- Item-specific license agreed upon to submission
- Description: