Corrigendum to “Development and Characterization of an Electroless Plated Silver/Cysteine Sensor Platform for the Electrochemical Determination of Aflatoxin B1

dc.contributor.authorWacoo, Alex Paul
dc.contributor.authorOcheng, Mathew
dc.contributor.authorWendiro, Deborah
dc.contributor.authorVuzi, Peter California
dc.contributor.authorHawumba, Joseph F.
dc.date.accessioned2021-12-10T17:16:14Z
dc.date.available2021-12-10T17:16:14Z
dc.date.issued2020
dc.description.abstractDevelopment and Characterization of an Electroless Plated Silver/Cysteine Sensor Platform for the Electrochemical Determination of Aflatoxin B1” [1], anti- Aflatoxin B1-Peroxidase antibody produced in rabbit IgG fraction of antiserum (product number SAB4200829) (Sigma Aldrich, Saint Louis, MO, USA) was mistakenly used as a reagent instead of anti-aflatoxin B1 antibody (product number A8679) (Sigma Aldrich, Saint Louis, MO, USA). Also in the results, Section 3.2 Electrochemical immune detection of aflatoxin B1 the reading was taken from positive potential which was due to impedance measurement. However, this paper is based on the electro-catalytic activity of horseradish peroxidase on the negative potential. In the method Section 2.3, therefore, entry 600nm should be -600 nm. In the result section, the whole of Section 3.2en_US
dc.identifier.citationWacoo, A. P., Ocheng, M., Wendiro, D., & Hawumba, J. F. (2020). Corrigendum to “Development and Characterization of an Electroless Plated Silver/Cysteine Sensor Platform for the Electrochemical Determination of Aflatoxin B1”. Journal of Sensors, 2020. https://doi.org/10.1155/2020/5370241en_US
dc.identifier.urihttps://doi.org/10.1155/2020/5370241
dc.identifier.urihttps://nru.uncst.go.ug/xmlui/handle/123456789/265
dc.language.isoenen_US
dc.publisherJournal of Sensorsen_US
dc.subjectElectroless Plated Silver/Cysteineen_US
dc.subjectElectrochemical Determinationen_US
dc.subjectAflatoxin B1”en_US
dc.titleCorrigendum to “Development and Characterization of an Electroless Plated Silver/Cysteine Sensor Platform for the Electrochemical Determination of Aflatoxin B1en_US
dc.typeArticleen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Corrigendum to “Development and Characterization of an Electroless Plated Silver Cysteine Sensor Platform for the Electrochemical Determination of Aflatoxin B1”.pdf
Size:
403.4 KB
Format:
Adobe Portable Document Format
Description:
Article
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: