Improved gas chromatography-flame ionization detector analytical method for the analysis of epoxy fatty acids
dc.contributor.author | Mubiru, Edward | |
dc.contributor.author | Shrestha, Kshitij | |
dc.contributor.author | Papastergiadis, Antonios | |
dc.contributor.author | De Meulenaer, Bruno | |
dc.date.accessioned | 2023-06-15T21:06:25Z | |
dc.date.available | 2023-06-15T21:06:25Z | |
dc.date.issued | 2014 | |
dc.description.abstract | In this study an improved method for analysis of epoxy fatty acids is reported. Data obtained from analysis of polar fatty acids has previously been presented, but due to the high number of compounds that co- elute in the polar fraction, the resultant chromatograms are complex which may lead to compromising the accuracy of the data. A three steps separation of fatty acid methyl esters (FAMEs) by solid-phase extraction (SPE) on a silica gel column to remove hydroxy fatty acid interferences was proposed. This approach is opposed to a two step separation procedure that has been often used to prevent analytical interferences caused by non-altered fatty acids. A gas chromatograph with a flame ionization detector (GC-FID) equipped with a polar CP-Sil 88TM column was used. Quantification was based on the use of methyl nonadecanoate (C19:0), as an internal standard. Individual mono epoxy fatty acids were well separated without co-eluting compounds. The optimized method was finally applied to screen epoxy fatty acids in 37 fresh oil samples. Results obtained for the total epoxy fatty acids were in the range 0.03ā2 mg gā1 of oil with repeatability coefficient of variation (CV) ranging from 2.8 to 9.9% for duplicate analysis showing that the results obtained are repeatable. | en_US |
dc.identifier.citation | Gaensbauer, J. T., Rakhola, J. T., Onyango-Makumbi, C., Mubiru, M., Westcott, J. E., Krebs, N. F., ... & Janoff, E. N. (2014). Impaired haemophilus influenzae type b transplacental antibody transmission and declining antibody avidity through the first year of life represent potential vulnerabilities for HIV-exposed but-uninfected infants. Clinical and Vaccine Immunology, 21(12), 1661-1667. http://dx.doi.org/10.1016/j.chroma.2013.10.025 | en_US |
dc.identifier.other | http://dx.doi.org/10.1016/j.chroma.2013.10.025 | |
dc.identifier.uri | https://nru.uncst.go.ug/handle/123456789/8938 | |
dc.language.iso | en | en_US |
dc.publisher | Clinical and Vaccine Immunolog | en_US |
dc.subject | Lipid oxidation | en_US |
dc.subject | Epoxy fatty acids | en_US |
dc.subject | Oxygenated polar fatty acids | en_US |
dc.subject | GC-FID FAMEs | en_US |
dc.title | Improved gas chromatography-flame ionization detector analytical method for the analysis of epoxy fatty acids | en_US |
dc.type | Article | en_US |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- Improved gas chromatography-flame ionization detector analytical.pdf
- Size:
- 828.44 KB
- Format:
- Adobe Portable Document Format
- Description:
- Article
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- license.txt
- Size:
- 1.71 KB
- Format:
- Item-specific license agreed upon to submission
- Description: