A Fiber-optic System for Measuring Single Excitation-Dual Emission Fluorescence Ratios in Real Time

dc.contributor.authorMcCarthy, John F.
dc.contributor.authorMagin, Richard L.
dc.contributor.authorKisaalita, William S.
dc.contributor.authorSlininger, Patricia J.
dc.date.accessioned2025-04-15T12:19:11Z
dc.date.available2025-04-15T12:19:11Z
dc.date.issued1992
dc.description.abstractThe development and subsequent evaluation of a fiber‐optic system for measuring single excitation—dual emission fluorescence ratios in real time is described. The design of the flashlamp excitation source, optics, electronics, and computer software is discussed. The dual emission pH sensitive fluorophore 1, 4‐dihydroxyphthalonitrile (1, 4‐DHPN) was used to test the performance of this system. The flexible design of this modular system permits the use of other single excitation—dual emission fluorophores by simply changing the appropriate optical filters. Upon a single 340–380‐nm excitation, pH‐sensitive emissions were monitored at 488 nm and 434 nm. The ratio of these emissions (488/434) was then computed in real time, for a 2 mM solution of 1, 4‐DHPN, while the pH was titrated over the range 5–9. The nonlinear, system‐dependent, calibration curve of pH versus the ratio of emission wavelengths was empirical fit by a fourth‐order polynomial (r2 = 0.995). Reliable pH measurements in the range 6–8 were obtained using concentrations of 1, 4‐DHPN as low as 50 μM. The standard deviation of pH measurements using a 1 mM solution of 1, 4‐DHPN, near neutral pH, was found to be approximately 0.1 pH unit
dc.identifier.citationMccarthy, J. F., Magin, R. L., Kisaalita, W. S., & Slininger, P. J. (1992). A Fiber‐Optic System for Measuring Single Excitation‐Dual Emission Fluorescence Ratios in Real Time. Biotechnology progress, 8(4), 360-368.
dc.identifier.urihttps://aiche.onlinelibrary.wiley.com/doi/abs/10.1021/bp00016a014
dc.identifier.urihttps://nru.uncst.go.ug/handle/123456789/10708
dc.language.isoen
dc.publisherBiotechnology progress
dc.titleA Fiber-optic System for Measuring Single Excitation-Dual Emission Fluorescence Ratios in Real Time
dc.typeArticle
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
A Fiber-optic System for Measuring Single Excitation-Dual Emission.pdf
Size:
858.33 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: