    Performance of Cryptococcal Antigen Lateral Flow Assay Using Saliva in Ugandans with CD4 ,<100

    Thumbnail
    View/Open
    Performance of Cryptococcal Antigen Lateral Flow Assay Using Saliva in Ugandans with CD4 <100 (213.1Kb)
    Date
    2014
    Author
    Kwizera, Richard
    Nguna, Joyce
    Kiragga, Agnes
    Nakavuma, Jesca
    Rajasingham, Radha
    Boulware, David R.
    Meya, David B.
    Metadata
    Show full item record
    Abstract
    Cryptococcal meningitis can best be diagnosed by cerebrospinal fluid India ink microscopy, cryptococcal antigen detection, or culture. These require invasive lumbar punctures. The utility of cryptococcal antigen detection in saliva is unknown. We evaluated the diagnostic performance of the point-of-care cryptococcal antigen lateral flow assay (CrAg LFA) in saliva.We screened HIV-infected, antiretroviral therapy naïve persons with symptomatic meningitis (n = 130) and asymptomatic persons with CD4+<100 cells/µL entering into HIV care (n = 399) in Kampala, Uganda. The diagnostic performance of testing saliva was compared to serum/plasma cryptococcal antigen as the reference standard.The saliva lateral flow assay performance was overall more sensitive in symptomatic patients (88%) than in asymptomatic patients (27%). The specificity of saliva lateral flow assay was excellent at 97.8% in the symptomatic patients and 100% in asymptomatic patients. The degree of accuracy of saliva in diagnosing cryptococcosis and the level of agreement between the two sample types was better in symptomatic patients (C-statistic 92.9, κ-0.82) than in asymptomatic patients (C-statistic 63.5, κ-0.41). Persons with false negative salvia CrAg tests had lower levels of peripheral blood CrAg titers (P<0.001).There was poor diagnostic performance in testing saliva for cryptococcal antigen, particularly among asymptomatic persons screened for preemptive treatment of cryptococcosis.
    URI
    https://nru.uncst.go.ug/handle/123456789/4300
    Collections
    • Medical and Health Sciences [3011]

    Research Dissemination Platform copyright © since 2021  UNCST
    Contact Us | Send Feedback
    Partners
     

     

    Browse

    All of NRU
    Communities & CollectionsBy Issue DateAuthorsTitlesSubjects
    This Collection
    By Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    Research Dissemination Platform copyright © since 2021  UNCST
    Contact Us | Send Feedback
    Partners