Measurement error of mean sac diameter and crown-rump length among pregnant women at Mulago hospital, Uganda

dc.contributor.authorAli, Sam
dc.contributor.authorKusaba Byanyima, Rosemary
dc.contributor.authorOnonge, Sam
dc.contributor.authorIctho, Jerry
dc.contributor.authorNyamwiza, Jean
dc.contributor.authorLoro, Emmanuel Lako Ernesto
dc.contributor.authorMukisa, John
dc.contributor.authorMusewa, Angella
dc.contributor.authorNalutaaya, Annet
dc.contributor.authorSsenyonga, Ronald
dc.contributor.authorKawooya, Ismael
dc.contributor.authorTemper, Benjamin
dc.contributor.authorKatamba, Achilles
dc.contributor.authorKalyango, Joan
dc.contributor.authorKaramagi, Charles
dc.date.accessioned2022-08-10T19:25:15Z
dc.date.available2022-08-10T19:25:15Z
dc.date.issued2018
dc.description.abstractUltrasonography is essential in the prenatal diagnosis and care for the pregnant mothers. However, the measurements obtained often contain a small percentage of unavoidable error that may have serious clinical implications if substantial. We therefore evaluated the level of intra and inter-observer error in measuring mean sac diameter (MSD) and crown-rump length (CRL) in women between 6 and 10 weeks’ gestation at Mulago hospital. Methods: This was a cross-sectional study conducted from January to March 2016. We enrolled 56 women with an intrauterine single viable embryo. The women were scanned using a transvaginal (TVS) technique by two observers who were blinded of each other’s measurements. Each observer measured the CRL twice and the MSD once for each woman. Intra-class correlation coefficients (ICCs), 95% limits of agreement (LOA) and technical error of measurement (TEM) were used for analysis. Results: Intra-observer ICCs for CRL measurements were 0.995 and 0.993 while inter-observer ICCs were 0.988 for CRL and 0.955 for MSD measurements. Intra-observer 95% LOA for CRL were ± 2.04 mm and ± 1.66 mm. Inter-observer LOA were ± 2.35 mm for CRL and ± 4.87 mm for MSD. The intra-observer relative TEM for CRL were 4.62% and 3.70% whereas inter-observer relative TEM were 5.88% and 5.93% for CRL and MSD respectively. Conclusions: Intra- and inter-observer error of CRL and MSD measurements among pregnant women at Mulago hospital were acceptable. This implies that at Mulago hospital, the error in pregnancy dating is within acceptable margins of ±3 days in first trimester, and the CRL and MSD cut offs of ≥7 mm and≥ 25 mm respectively are fit for diagnosis of miscarriage on TVS. These findings should be extrapolated to the whole country with caution. Sonographers can achieve acceptable and comparable diagnostic accuracy levels of MSD and CLR measurements with proper training and adherence to practice guidelines.en_US
dc.identifier.citationAli, S., Byanyima, R. K., Ononge, S., Ictho, J., Nyamwiza, J., Loro, E. L. E., ... & Karamagi, C. (2018). Measurement error of mean sac diameter and crown-rump length among pregnant women at Mulago hospital, Uganda. BMC Pregnancy and Childbirth, 18(1), 1-6. https://doi.org/10.1186/s12884-018-1769-2en_US
dc.identifier.urihttps://doi.org/10.1186/s12884-018-1769-2
dc.identifier.urihttps://nru.uncst.go.ug/handle/123456789/4266
dc.language.isoenen_US
dc.publisherBMC Pregnancy and Childbirthen_US
dc.subjectMean sac diameteren_US
dc.subjectCrown-rump lengthen_US
dc.subjectMeasurement erroren_US
dc.titleMeasurement error of mean sac diameter and crown-rump length among pregnant women at Mulago hospital, Ugandaen_US
dc.typeArticleen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Measurement error of mean sac diameter.pdf
Size:
1.58 MB
Format:
Adobe Portable Document Format
Description:
Article
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: