Validity of the Rapid Strip Assay Test for Detecting HBsAg in Patients Admitted to Hospital in Uganda

dc.contributor.authorSeremba, E.
dc.contributor.authorOcama, P.
dc.contributor.authorOpio, C.K.
dc.contributor.authorKagimu, M.
dc.contributor.authorYuan, H.J.
dc.contributor.authorAttar, N.
dc.contributor.authorThomas, D.L.
dc.contributor.authorLee, W.M.
dc.date.accessioned2022-05-01T22:05:16Z
dc.date.available2022-05-01T22:05:16Z
dc.date.issued2010
dc.description.abstractCommercially available rapid strip assays (RSAs) for hepatitis B surface antigen (HBsAg) are used for most routine clinical testing in sub-Saharan Africa. This study evaluated the validity of RSA and a more sophisticated enzyme immunoassay (EIA) with confirmation by nucleic acid testing (NAT) in hospitalized patients in Uganda. Sera from 380 consecutive patients collected and tested for HBsAg and anti-HIV in Kampala, Uganda by RSA were sent frozen to Dallas for EIA including HBsAg, total anti-hepatitis B core, hepatitis B e antigen, and anti-HIV. NAT was performed on all HBsAg-positives and on a random sample of 102 patients that were HBsAgnegative by both assays. Overall, 31 (8%) were HBsAg positive by RSA while 50 (13%) were HBsAg-positive by EIA; 26 were concordant between the two assays. Of 55 HBsAg-positive patients, nearly all showed detectable serum hepatitis B virus (HBV) DNA by bDNA (46) or PCR (4) assay. The 26 patients who were HBsAg positive by both EIA and RSA had significantly higher median serum HBV DNA levels than the 24 patients who were HBsAg positive by EIA alone. An additional 12/102 (12%) HBsAg negative patients had very low serum HBV DNA levels by NAT. Several differences in expected results of serologic testing were observed in this large series of African patients. RSA HBsAg testing is less sensitive than EIA; even EIA failed to detect allHBVDNApositive sera.Amorecomplex testing protocol than RSA alone will be needed in Africa to improve patient care. J. Med. Virol. 82:1334–1340, 2010. 2010 Wiley-Liss, Inc.en_US
dc.identifier.citationSeremba, E., Ocama, P., Opio, C. K., Kagimu, M., Yuan, H. J., Attar, N., ... & Lee, W. M. (2010). Validity of the rapid strip assay test for detecting HBsAg in patients admitted to hospital in Uganda. Journal of medical virology, 82(8), 1334-1340. DOI 10.1002/jmv.21813en_US
dc.identifier.other10.1002/jmv.21813
dc.identifier.urihttps://nru.uncst.go.ug/handle/123456789/3111
dc.language.isoenen_US
dc.publisherJournal of medical virologyen_US
dc.subjectRapid strip assayen_US
dc.subjectEnzyme immunoassayen_US
dc.subjectNucleic acid testingen_US
dc.subjectHBsAgen_US
dc.titleValidity of the Rapid Strip Assay Test for Detecting HBsAg in Patients Admitted to Hospital in Ugandaen_US
dc.typeArticleen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Validity of the Rapid Strip Assay Test for Detecting.pdf
Size:
171.23 KB
Format:
Adobe Portable Document Format
Description:
Article
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: