A critical analysis of physiochemical properties influencing pit latrine emptying and feacal sludge disposal in Kampala Slums, Uganda

dc.contributor.authorZziwa, Ahamada
dc.contributor.authorNabulime, Maureen N.
dc.contributor.authorKiggundu, Nicholas
dc.contributor.authorKambugu, Robert
dc.contributor.authorKatimbo, Abia
dc.contributor.authorKomakech, Allan J.
dc.date.accessioned2022-12-25T10:49:59Z
dc.date.available2022-12-25T10:49:59Z
dc.date.issued2016
dc.description.abstractInadequate information on physiochemical properties of faecal sludge leads to inappropriate design of pit emptying devices and poor faecal sludge disposal contributing to environmental pollution. This study undertook a critical analysis of physiochemical properties of feacal sludge that influence design and performance of pit emptying devices and faecal sludge disposal for improved faecal sludge management in urban slums. The physiochemical properties determined were; Moisture content (MC), ash content (AC), total solids (TS), volatile solids (VS), nitrogen (N), phosphorous (P), potassium (K) and pH. Samples were collected from 55 unlined pits at depths of 0, 0.5, 1 and 1.5 m from pit surface. The unlined pits in this study were purposively selected from slums in Kampala. A sample of 300 g was sucked from each depth using a manual sampling tool and emptied into a plastic container. The container was then wrapped in a black plastic bag and transported in cooler boxes to the lab for analysis. The properties were subjected to Principal Component Analysis to isolate the critical parameters that affect pit emptying and faecal sludge disposal. The mean results were: MC of 86 ± 8.37%; TS of 0.14 ± 0.08 g/g wet sample; VS of 0.73 ± 0.32 g/g dry sample; pH of 8.0 ± 1.5; AC of 0.35± 0.18 g/g dry sample; TN of 3.5 ± 0.08%; K of 2.2± 0.13% and P of 1.4± 0.05%. It was concluded that physiochemical properties in Ugandan pits are comparable to those of global pits except for the acidic conditions at top surface in some pits, and higher moisture content in pits due to the high water table. PCA results showed that moisture content and total solids affected pit emptying techniques while fractional content of N, P and pH affect most choice of faecal sludge disposal technique.en_US
dc.identifier.citationZziwa, A., Nabulime, M. N., Kiggundu, N., Kambugu, R., Katimbo, A., & Komakech, A. J. (2016). A critical analysis of physiochemical properties influencing pit latrine emptying and feacal sludge disposal in Kampala Slums, Uganda. African Journal of Environmental Science and Technology, 10(10), 316-328. DOI: 10.5897/AJEST2016.2163en_US
dc.identifier.issn1996-0786
dc.identifier.otherDOI: 10.5897/AJEST2016.2163
dc.identifier.urihttps://nru.uncst.go.ug/handle/123456789/6526
dc.language.isoenen_US
dc.publisherAfrican Journal of Environmental Science and Technologyen_US
dc.subjectPit latrineen_US
dc.subjectfaecal sludge managementen_US
dc.subjectdeveloping countriesen_US
dc.titleA critical analysis of physiochemical properties influencing pit latrine emptying and feacal sludge disposal in Kampala Slums, Ugandaen_US
dc.typeArticleen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
A critical analysis.pdf
Size:
417.09 KB
Format:
Adobe Portable Document Format
Description:
Article
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: