Evaluation of a Low-Cost Bubble CPAP System Designed for Resource-Limited Settings

dc.contributor.authorBennett, Desmond J.
dc.contributor.authorCarroll, Ryan W.
dc.contributor.authorKacmarek, Robert M.
dc.date.accessioned2022-08-01T13:41:42Z
dc.date.available2022-08-01T13:41:42Z
dc.date.issued2018
dc.description.abstractRespiratory compromise is a leading contributor to global neonatal death. CPAP is a method of treatment that helps maintain lung volume during expiration, promotes comfortable breathing, and improves oxygenation. Bubble CPAP is an effective alternative to standard CPAP. We sought to determine the reliability and functionality of a low-cost bubble CPAP device designed for low-resource settings. METHODS: The low-cost bubble CPAP device was compared to a commercially available bubble CPAP system. The devices were connected to a lung simulator that simulated neonates of 4 different weights with compromised respiratory mechanics ( 1, 3, 5, and 10 kg). The devices’ abilities to establish and maintain pressure and flow under normal conditions as well as under conditions of leak were compared. Multiple combinations of pressure levels (5, 8, and 10 cm H2O) and flow levels (3, 6, and 10 L/min) were tested. The endurance of both devices was also tested by running the systems continuously for 8 h and measuring the changes in pressure and flow. RESULTS: Both devices performed equivalently during the no-leak and leak trials. While our testing revealed individual differences that were statistically significant and clinically important (>10% difference) within specific CPAP and flow-level settings, no overall comparisons of CPAP or flow were both statistically significant and clinically important. Each device delivered pressures similar to the desired pressures, although the flows delivered by both machines were lower than the set flows in most trials. During the endurance trials, the low-cost device was marginally better at maintaining pressure, while the commercially available device was better at maintaining flow. CONCLUSIONS: The low-cost bubble CPAP device evaluated in this study is comparable to a bubble CPAP system used in developed settings. Extensive clinical trials, however, are necessary to confirm its effectiveness.en_US
dc.identifier.citationBennett, D. J., Carroll, R. W., & Kacmarek, R. M. (2018). Evaluation of a low-cost bubble CPAP system designed for resource-limited settings. Respiratory Care, 63(4), 395-403. Doi: 10.4187/respcare.05762en_US
dc.identifier.other10.4187/respcare.05762
dc.identifier.urihttps://nru.uncst.go.ug/handle/123456789/4240
dc.language.isoenen_US
dc.publisherRespiratory Careen_US
dc.subjectCPAPen_US
dc.subjectBubbleCPAPen_US
dc.subjectRespiratory distressen_US
dc.subjectLow-resource settingsen_US
dc.subjectUgandaen_US
dc.subjectNeonatesen_US
dc.titleEvaluation of a Low-Cost Bubble CPAP System Designed for Resource-Limited Settingsen_US
dc.typeArticleen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Evaluation of a Low-Cost Bubble CPAP System Designed for.pdf
Size:
1.63 MB
Format:
Adobe Portable Document Format
Description:
Article
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: