Evaluation of a lateral flow device for in-field detection of Banana Xanthomonas Wilt and its application in tracking the systemicity of Xanthomonas campestris pv. musacearum

dc.contributor.authorKaramura, Georgina
dc.contributor.authorOchola, Dennis
dc.contributor.authorSmith, Julian
dc.contributor.authorKubiriba, Jerome
dc.contributor.authorKaramura, Eldad
dc.date.accessioned2022-05-27T14:25:58Z
dc.date.available2022-05-27T14:25:58Z
dc.date.issued2016
dc.description.abstractEarly detection of Banana Xanthomonas Wilt (BXW) in the field and immediate destruction of infected plants or plant tissue are key control methods to prevent the introduction and spread of BXW. This requires rapid, cost-effective and an on- site diagnostic tool to detect the bacterium, Xanthomonas campestris pv musacearum (Xcm). Polymerase chain reaction (PCR) detection technique for BXW is efficient but requires expensive equipment and knowledgeable expertise; this limits PCR application to the laboratory. This study therefore was carried out to evaluate the enzyme-linked immunosorbent assay (ELISA) tool configured as a lateral flow device (LFD) for detection of Xcm. Studies on the systemicity of Xcm in banana were carried out using the BXW-LFD in a field trial of 300 banana plants of Pisang Awak inoculated with the Xcm at Kiifu Forest, Mukono District, Uganda. Pseudo-stem samples from symptomatic and asymptomatic suckers were collected and tested with the LFD and the results compared with conventional PCR using the GspDm BXW primers. The LFD was able to detect Xcm 3 days post inoculation (dpi), 2 cm above and below inoculation site, 15 to 35 days in the pseudo-stem, 35 to 42 days to reach the corm and 81 days in the lateral roots. The rate of Xcm movement in banana was found to be sigmoid in nature, leveling off as the bacteria moved down the pseudo-stem towards the corm. Conventional PCR was only 24% more sensitive than the LFD. The use of the BXW LFD can therefore boost BXW control measures through improved surveillance and quarantine services to arrest the introduction and spread of the disease within and between national borders.en_US
dc.identifier.citationKaramura, G., Ochola, D., Smith, J., Kubiriba, J., & Karamura, E. (2016). Evaluation of a lateral flow device for in-field detection of Banana Xanthomonas Wilt and its application in tracking the systemicity of Xanthomonas campestris pv. musacearum. African Journal of Agricultural Research, 11(25), 2250-2256. DOI: 10.5897/AJAR2016.10966en_US
dc.identifier.other10.5897/AJAR2016.10966
dc.identifier.urihttps://nru.uncst.go.ug/handle/123456789/3579
dc.language.isoenen_US
dc.publisherAfrican Journal of Agricultural Researchen_US
dc.subjectBanana Xanthomonas Wilt lateral flow device (BXW LFD)en_US
dc.subjectBanana Xanthomonas wilten_US
dc.subjectXanthomonas campestris pv musacearumen_US
dc.subjectComplete systemicityen_US
dc.subjectIncomplete systemicityen_US
dc.subjectLateral flow deviceen_US
dc.titleEvaluation of a lateral flow device for in-field detection of Banana Xanthomonas Wilt and its application in tracking the systemicity of Xanthomonas campestris pv. musacearumen_US
dc.typeArticleen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Evaluation of a lateral flow device for in-field detection.pdf
Size:
299.78 KB
Format:
Adobe Portable Document Format
Description:
Article
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: